Imagine designing a temperature sensor using a voltage divider that outputs an exact 5.00Β V signal. The moment you connect it to an analog meter or ADC with low resistance, that signal collapses down to less than 1Β V.
This signal collapse happens because of loading error, where the measuring device draws current and unintentionally alters the sensor circuit itself.
πInteractive diagram
Before we solve this collapse, let us look at the mathematics behind why connecting a load distorts an otherwise balanced sensor.
The Mechanism of Signal Loading
In an unloaded potential divider with supply voltage Vsβ and resistors R1β and R2β, no current leaves the midpoint. The output voltage is governed by the standard ratio Vunloadedβ=Vsββ
R1β+R2βR2ββ
When you attach a load resistance (RLβ) directly to the output, RLβ is placed in parallel with R2β. This drops the effective bottom resistance to Reqβ=R2ββ₯RLβ=R2β+RLβR2ββ
RLββ
Let us calculate a concrete scenario: assume Vsβ=10Β V, high-value sensor resistors R1β=100Β kΞ© and R2β=100Β kΞ©, and a low load resistance RLβ=10Β kΞ©.
First, the parallel combination gives Reqβ=100Β kΞ©+10Β kΞ©100Β kΞ©Γ10Β kΞ©β=9.09Β kΞ©. Substituting this back into the voltage divider yields Vloadedβ=10Β Vβ
100Β kΞ©+9.09Β kΞ©9.09Β kΞ©β=0.833Β V
πInteractive diagram
The load causes an 83.3% voltage drop because the sensor cannot supply enough current without dropping voltage across R1β. How can we transfer the full 5.00Β V signal into RLβ without pulling any current from the divider?
Eliminating Loading with a Voltage Follower
An ideal operational amplifier has infinite input impedance (Rinβββ) and zero output impedance (Routββ0). In a unity-gain buffer configuration, the output connects directly back to the inverting input (Vββ).